Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of Modern Laboratory Medicine ; (4): 92-96, 2017.
Article in Chinese | WPRIM | ID: wpr-613428

ABSTRACT

Objective To evaluate the performance alarms and parameters generated by hematology analyzer during detection of circulating sezary cells of peripheral blood smears.Methods Blood samples from patients with Sezary syndrome (n=21) were studied with Sysmex XN-9000 analyzer,and compared to patients with benign or tumoral skin lesions (n=48) and patients with chronic lymphoproliferative B-cell diseases (n=55) and normal person (n=45) used as control.Results In present series,the value of structural lymphoid parameters (ly-x and ly-z) and the alarm Blast/Abn Lympho were statistically higher in Sezary cases than in control cases (U=37,40,44,55,38,41,all P<0.05).Screening Sezary cells critical values of ly-x and ly-z determined by ROC curve were greater than or equal to 86 and was more than or equal to 68.The combination of above three indexes up (i.e.alarm Blast/Abn Lympho> 100,ly-x=86 and ly-z>68) sensitivity and specificity respectively for 100 % and 92.1 %,in order to get the best screening Sezary cells diagnostic efficiency.In addition,the value of ly-x was associated to the count of circulating Sezary cells and value of ly-z to the presence of large Sezary cells,both parameters described as prognostic factors.Conclusion The combination of alarm Blast/Abn Lympho and structural parameters (ly-x/ ly-z/ly-y) may allow to define rule of blood slide review to screen circulating Sezary cells.

2.
Chinese Journal of Clinical Laboratory Science ; (12): 101-104, 2017.
Article in Chinese | WPRIM | ID: wpr-514020

ABSTRACT

Objective To evaluate the reliability of the white precursor cell (WPC) channel on the Sysmex XN-9000 hematology analyzer (XN-9000) in giving the abnormal white blood cell (WBC) alarm.Methods A total of 520 blood samples with abnormal WBC alarm from the Sysmex XE-2100 (XE-2100) and XN-9000 were performed the manual peripheral blood smear review,and their results were analyzed.Results The specificity of the XN-9000 WPC channel in the blast alarm was significantly higher than that of XE-2100 (x2 =6.98,P<0.05),while the false positive rate of the XN-9000 (36%) significantly lower than that of XE-2100 (64%,x2 =6.18,P < 0.05).The overall efficiency of the XN-9000 WPC channel in identifying blasts and abnormal lymphocytes (90.4% and 94.4%) was significantly higher than that of the XE-2100 (72.2% and 80.1%,x2 =5.6 and 6.33,P < 0.05).Under the automatic reflex analysis mode of WPC channel,the specificity and overall efficiency of the WPC channel in identifying blasts and abnormal lymphoeytes of all the detected samples were significantly higher than those of the WDF channel (x2 =6.15,4.14,6.02 and 4.88,P <0.05).The total review rate of the XN-9000 (WDF/WPC) was significantly lower than that of the XE-2100 (x2 =4.33,P < 0.05).Similarly,the review rate of the XN-9000 for the blast/abnormal lymphocyte alarm (84/260,32%) was significantly lower than that of the XE-2100 (107/260,41%) (x2 =4.38,P<0.05).Conclusion Compared with the XE-2100,the XN-9000 WPC channel can improve the overall efficiency of the blast/abnormal lymphocyte alarm,reduce the false positive rate and the review rate,and then improve the efficiency of clinical laboratories.

3.
Journal of Modern Laboratory Medicine ; (4): 123-126,129, 2016.
Article in Chinese | WPRIM | ID: wpr-605424

ABSTRACT

Objective To evaluate the performance of the CellaVisionTM DM96 analyzer during detection of intracellular para-sites of peripheral blood smears.Methods This study compared the detection rates of Plasmodium and Babesia species on peripheral blood smears utilizing the CellaVision DM9 6 with the rates for a routine red blood cell morphology scan.A total of 307 slides were analyzed,consisting of 142 slides positive for Plasmodium or Babesia species and 165 negative controls. Slides were blinded,randomized,and analyzed by CellaVision 9 6 and microscopy for red cell morphology scans.The technolo-gists were blinded to prior identification.Results The examination of common technician and blood professional technician, whether using optical microscope or CellaVision DM9 6 could accurately identify all the negative control,its specificity was 100%.The sensitivity of blood professionals using CellaVision DM96 was not statistically significant in the sensitivity of the laboratory and the use of light microscopy for the detection of Plasmodium parasites (χ2=0.24,0.03,0.43,P>0.05).The higher percentage of Plasmodium in blood smear,the higher detection rate of CellaVision DM9 6 .When the blood smear Plas-modium white rate greater than 1%,only 2 contain Plasmodium falciparum samples were negative for the miscarriage of j us-tice.The blood smear percentage was higher than 2% CellaVision of Plasmodium DM96 will all the blood smear 100% cor-rect interpretation.Conclusion This study demonstrates that CellaVision had the potential to detect intracellular parasites in routine screening of blood smears resource for storing images to be used for educational purposes,including training technol-ogists in the detection of intracellular parasites.

SELECTION OF CITATIONS
SEARCH DETAIL